PR6 – Elster Honeywell Pulse Communication Modules
The PR6 pulse module is designed with advanced bi-directional inductive technology helping to enhance the efficiency of network system management, leakage control and reading of water meters remotely. This module is tamper resistant and rated to IP68.
Type
Retrofittable Inductive Pulse with 2m Length Cable
Compatibility
V200, V210 & V220 Elster Water Meters (2012 models onwards)
Output
Primary & Secondary Pulse Channels (see datasheet for details)
Addition Outputs
Direction Flag, Compensation Flag, Tamper
Power Source
3.6V Lithium Battery (7-14 years life)
PR7 – Elster Honeywell Pulse Communication Modules
The PR7 pulse module is designed with advanced bi-directional inductive technology helping to enhance the efficiency of network system management, leakage control and reading of water meters remotely. This module is tamper resistant and rated to IP68.
Type
Retrofittable Inductive Pulse with 5m Length Cable
Compatibility
H4000, C4000 & C4200 Elster Water Meters
Output
Primary & Secondary Pulse Channels (see datasheet for details)
Addition Outputs
Direction Flag, Compensation Flag, Tamper
Power Source
3.6V Lithium Battery (7-14 years life)
FALCON- Elster Honeywell M-Bus Communication Modules
The FALCON M-Bus module is designed with advanced bi-directional inductive technology helping to enhance the efficiency of network system management, leakage control and reading of water meters remotely. This module is tamper resistant and rated to IP68.
Type
Retrofittable Inductive M-Bus with 2m Length Cable
Compatibility
V200, V210, H4000, C4000 & C4200 Elster Water Meters
Output
M-Bus Protocol Standard EN 13757
M-Bus Interface
TI TSS721 with 2 x 2150 ohm protective resistor
Power Source
M-Bus Powered with 3.6V Lithium Battery Back Up
T110 – Elster Honeywell Pulse T Probe
The Elster T110 probe is fitted with a 100Ω series resistor to protect the reed switch from a power surge. The duty cycle of the switch closure is typically 70% on, 30% off.
Type
Retrofittable TL2 Variant Reed Switch Pulse (JTA6002) with 5m Length Cable
Compatibility
V100 (PSM) Elster Water Meters
Output
1 Pulse Channel
Addition Outputs
Tamper (Loopback)
Power Source
Volt Free
JTA4600 – Elster Honeywell Pulse T110 Probe c/w Splitter
The Elster JTA4600 probe is fitted with a 100Ω series resistor to protect the reed switch from a power surge. The duty cycle of the switch closure is typically 70% on, 30% off. It has a pulse splitter fitted in series enabling two pulse outputs.
Type
Retrofittable Reed Switch Pulse c/w Splitter (2 x 5m Length Cable)
Compatibility
V100 (PSM) Elster Water Meters
Output
1 Pulse Channel Split into 2 Outputs
Addition Outputs
Tamper (Loopback)
Power Source
Volt Free
T125 – Elster Reed Switch Pulse Unit (Non-Inductive Register)
The Elster T125 pulse unit fits a range of older type Elster meters with non-inductive registers. When ordering, ensure that you require this unit and not the PR6 inductive pulse module, if in doubt, please contact us for clarification.
Type
Retrofittable Reed Switch Pulse (RR5LRPX005X) with 5m Length Cable
Compatibility
V200 & V210 Elster Water Meters (Old type with grey stroud and non-inductive register)
Output
1 Pulse Channel
Addition Outputs
Tamper (Loopback)
Power Source
Volt Free
T140 – Elster Reed Switch Pulse Unit (Non-Inductive Register)
The Elster T140 (PG100 & 5000M4072) dovetail pulse unit fits a range of older type Elster meters with non-inductive registers. When ordering, ensure that you require this unit and not the PR7 inductive pulse module, if in doubt, please contact us for clarification.
Type
Dovetail Reed Switch Pulse with 5m Length Cable
Compatibility
H4000, S2000, C4000 & C4200 Elster Water Meters with Non-Inductive Registers
Output
1 Pulse Channel
Addition Outputs
N/A
Power Source
Volt Free
T150 (BPG20) – Elster Opto Pulse Unit (Non-Inductive Register)
The Elster T150 high-resolution opto pulse unit fits a range of older type Elster meters with non-inductive registers. When ordering, ensure that you require this unit and not the PR7 inductive pulse module, if in doubt, please contact us for clarification.
Type
Retrofittable Opto Pulse with 5m Length Cable
Compatibility
H4000, S2000, C4000 & C4200 Elster Water Meters with Non-Inductive Register
Output
1 Pulse Channel
Addition Outputs
N/A
Power Source
6-15V Required to power opto
T131 – Elster Reed Switch Pulse Unit
LUAA6006 – Elster Pulse T131 c/w Splitter
The Elster LUAA6006 is a disc type low-resolution pulse unit to suit the Kent H3000, V300 and C3200 water meters. It has a pulse splitter fitted in series enabling two pulse outputs.
Type
Retrofittable Reed Switch Pulse c/w Splitter (2 x 5m Length Cable)
Compatibility
H3000, V300 & C3200 Elster Water Meters
Output
1 Pulse Channel Split into 2 Outputs
Addition Outputs
N/A
Power Source
Volt Free
IN-Z61 – Pulse Module
Pulse Module For Elster Jeavons BK Diaphragm Gas Meters
The IN-Z61 is a retro-fittable pulse unit enabling it to be easily fitted on site without disturbing the calibration seal or interrupting the gas supply.
Type : Reed Switch Pulse Compatible With : BK gas meters
Voltage : Umax = 24V DC Current : Imax = 50mA Power : Pmax = 0.25 W
Closing Time : Tmin = 0.25 s Resistance : Rmax = 0.5Ω (closed)